Conductivity Calibration Solution

Conductivity standards for calibrating conductivity and salinity meters.

Price range: $60.00 through $250.00 ex GST

Product Information

Key Features

  • Three standard values — 1,000 µS/cm (1 mS/cm), 10,000 µS/cm (10 mS/cm) and 50,000 µS/cm (50 mS/cm)
  • Covers fresh, brackish and near-seawater conductivity so the standard can be matched to the water you actually measure
  • Ready to use straight from the container — no dilution or preparation
  • Suits single-point and multi-point calibration on most commercial conductivity, salinity and TDS meters
  • Compatible with handheld meters such as the YSI EC300A and YSI Pro30 and with inline conductivity probes
  • Supplied in 1 L and 5 L bottles; 500 mL available on request
  • Stocked in Australia by Fresh By Design for RAS, hatchery, grow-out and aquaponic sites
  • Choosing your standard: pick the value closest to the water you measure — 1,000 µS/cm for fresh water and aquaponics, 10,000 µS/cm for brackish and estuarine water, 50,000 µS/cm for seawater and marine systems; calibrating on a standard far from your working range is the most common cause of a meter reading wrong.

Specifications

Standard valueBottle sizeProduct codeWater it matches
1,000 µS/cm (1 mS/cm)1 LCS1000-1Fresh water, aquaponics, low-conductivity RAS and town water
1,000 µS/cm (1 mS/cm)5 LCS1000-5As above, bulk for multi-meter or whole-site calibration
10,000 µS/cm (10 mS/cm)1 LCS10000-1Brackish and estuarine water, part-strength saltwater systems
10,000 µS/cm (10 mS/cm)5 LCS10000-5As above, bulk for multi-meter or whole-site calibration
50,000 µS/cm (50 mS/cm)1 LCS50000-1Seawater and marine systems — the closest of the three to full-strength seawater
50,000 µS/cm (50 mS/cm)5 LCS50000-5As above, bulk for multi-meter or whole-site calibration
500 mL bottles500 mLCS1000-0.5 / CS10000-0.5 / CS50000-0.5All three values available in 500 mL on request — contact Fresh By Design
Reference temperatureNot published by supplier—Conductivity standards are normally certified at 25 °C; confirm the value and reference temperature printed on the bottle label before calibrating
Shelf life / opened-bottle lifeNot published by supplier—Check the expiry printed on the bottle; keep containers sealed, as evaporation raises the standard's true value

Frequently Asked Questions

Spare Parts & Consumables

No products were found matching your selection.

Related Products

Have a question or need a custom solution?

Our team is here to help you find the right equipment for your project.